U-Anchor 2000 Single Ply

Generic, PVC, TPO, KEE: $42.50

With Ring: $47.50

EPDM: $53.50

With Ring: $58.30

Available for the following roofing manufacturers: Generic, Carlislie, Verisco, Mule-Hide, WeatherShield, Firestone, GenFlex, Johns Manville, GAF, IB Roof Systems, Sarnfil, Duro-Last, Flex, Fiberite, US-Ply.

The U-Anchor 2000 is a integrated solution for all full adhered single ply membrane applications, consisting of an encapsulated U-Anchor plate with a 3/8”-16 S.S. fused to a 16”X16” membrane target. The target is welded to a fully adhered roof membrane. The Target can be made from the same brand as the roofing material. Available with and without a membrane attachment ring. Please specify a brand when possible. Nuts and lock washers sold separately. Alternate colors other than white are available on request.

Testing & Engineering Reports

Test 1Download Full Report

Test Pressure: 550lbs (250kg)
Deck: Min ½” Wood, Metal, Lightweight Concrete, or Structural Concrete.
Cover Board: Min ¼” – Ribbon Adhered Dens-Deck Prime, Securock, or High Density ISO Board.
Membrane: Any Fully Adhered TPO or PVC Roof Membrane

Test 2Download Full Report

Test Pressure: 700lbs (318kg)
Deck: Min ½” Wood, Metal, Lightweight Concrete, or Structural Concrete.
Insulation Board: (Optional) Any UL Classified Min 1.5” Mechanically Attached ISO Board.
Cover Board: Min ½” High Density ISO Board, Ribbon Adhered at 12” O.C.
Membrane: Any Fully Adhered TPO or PVC Roof

Test 3Download Full Report

Test Pressure: 950lbs (431kg)
Deck: Min ½” Wood, Metal, Lightweight Concrete, or Structural Concrete.
Insulation Board: (Optional) Any UL Classified Min 1.5” Mechanically Attached ISO Board.
Cover Board: Min ¼” Dens-Deck Prime or Securock, Ribbon Adhered at 12” O.C.
Membrane: Any Fully Adhered TPO or PVC Roof

Test 4Download Full Report

Test Pressure: 650lbs (295kg)
Deck: Min ½” Wood, Metal, Lightweight Concrete, or Structural Concrete.
Insulation Board: (Optional) Any UL Classified Min 1.5” Ribbon Adhered ISO Board.
Cover Board: Min ¼” Dens-Deck Prime or Securock, Ribbon Adhered at 12” O.C.
Membrane: Any Fully Adhered TPO or PVC Roof

Test 5Download Full Report

Test Pressure: 750lbs (340kg)
Deck: Min ½” Wood, Metal, Lightweight Concrete, or Structural Concrete.
Insulation Board: (Optional) Any UL Classified Min 1.5” Subsequently Attached.
Cover Board: Min ¼” Dens-Deck Prime or Securock, Mechanically Attached at 16 fasteners per 4’ X 8’ board.
Membrane: Any Fully Adhered TPO or PVC Roof

Test 7Download Full Report

Test Pressure: 650lbs (295kg)
Deck: Min ½” Wood, Metal, Lightweight Concrete, or Structural Concrete.
Cover Board: Min ½” High Density ISO, Ribbon Adhered at 12” O.C.
Membrane: Any Fully Adhered TPO or PVC Roof

Test 8Download Full Report

Test Pressure: 1050lbs (476kg)
Deck: Min ½” Wood, Metal, Lightweight Concrete, or Structural Concrete.
Cover Board: Min ½” High Density ISO, Mechanically Attached at 16 fasteners per 4’ X 8’ board.
Membrane: Any Fully Adhered TPO or PVC Roof

Test 9

Test Pressure: 700lbs (318kg)
Deck: Min ½” Wood, Metal, Lightweight Concrete, or Structural Concrete.
Insulation Board: Any UL Classified Min 1.5” Ribbon Adhered ISO Board..
Membrane: Any Fully Adhered TPO or PVC Roof

Test 10Download Full Report

Test Pressure: 500lbs (227kg)
Deck: Min ½” Wood, Metal, Lightweight Concrete, or Structural Concrete.
Insulation Board: Any UL Classified Min 1.5” Mechanically Attached ISO Board.
Membrane: Any Fully Adhered TPO or PVC Roof

Test 11

Test Pressure: 991lbs (450kg)
Deck: Min ½” Wood, Metal, Lightweight Concrete, or Structural Concrete.
Insulation Board: (Optional) Any UL Classified Min 1.5” Mechanically Attached or Ribbon Adhered ISO Board.
Cover Board: (optional) Min ¼” Dens-Deck Prime, Securock, Mechanically Attached Ribbon or Adhered.
Membrane: Any Fully Adhered TPO or PVC Roof

Disclaimer: The attached information represents tension loads or loads applied to the product in an upward direction, perpendicular to the roof surface. Roof assemblies must be secured in accordance with typical roof industry installation practices and attachment patterns specified in the individual test report selected. Third party test reports are available for both tension as well as shear for each roof assembly. Loads are listed in ultimate force without the inclusion of a safety factor. Allowable loads should be calculated using a safety factor consistent with ASCE7 and ASTM D6630. Actual safety factor identification and overall force load calculations are the responsibility of the qualified design professional of record for each project.