U-Anchor 2000 Single Ply Test Results

Disclaimer: The attached information represents tension loads or loads applied to the product in an upward direction, perpendicular to the roof surface. Roof assemblies must be secured in accordance with typical roof industry installation practices and attachment patterns specified in the individual test report selected. Third party test reports are available for both tension as well as shear for each roof assembly. Loads are listed in ultimate force without the inclusion of a safety factor. Allowable loads should be calculated using a safety factor consistent with ASCE7 and ASTM D6630. Actual safety factor identification and overall force load calculations are the responsibility of the qualified design professional of record for each project.

 

Test #

Roof Assembly Description

Ultimate Pressure

Assembly Design

Testing Information


1-1

Deck: Min ½” Wood, Metal, Lightweight Concrete, or Structural Concrete. 

Cover Board: Min ¼” – Ribbon Adhered Dens-Deck Prime, Securock, or High Density ISO Board.

Membrane: Any Fully Adhered TPO or PVC Roof  Membrane

550lbs (250kg)

test-300x197.jpg

1-2

Deck: Min ½” Wood, Metal, Lightweight Concrete, or Structural Concrete.
 
Insulation Board:  (Optional) Any UL Classified Min 1.5” Mechanically Attached ISO Board.

Cover Board: Min ½” High Density ISO Board, Ribbon Adhered at 12” O.C.

Membrane: Any Fully Adhered TPO or PVC Roof

700lbs (318kg)

test-photo-2-31-300x297.jpg

1-3

Deck: Min ½” Wood, Metal, Lightweight Concrete, or Structural Concrete. 

Insulation Board:  (optional) Any UL Classified Min 1.5” Mechanically Attached ISO Board.

Cover Board: Min ¼” Dens-Deck Prime or Securock, Ribbon Adhered at 12” O.C.

Membrane: Any Fully Adhered TPO or PVC Roof

950lbs (431kg)

test-photo-2-3-300x297.jpg

1-4

Deck: Min ½” Wood, Metal, Lightweight Concrete, or Structural Concrete. 

Insulation Board:  (optional) Any UL Classified Min 1.5” Ribbon Adhered ISO Board.

Cover Board: Min ¼” Dens-Deck Prime or Securock, Ribbon Adhered at 12” O.C.

Membrane: Any Fully Adhered TPO or PVC Roof

650lbs (295kg)

test-photo-4-293x300.jpg

1-5

Deck: Min ½” Wood, Metal, Lightweight Concrete, or Structural Concrete. 

Insulation Board: (Optional) Any UL Classified Min 1.5” Subsequently Attached.

Cover Board: Min ¼” Dens-Deck Prime or Securock, Mechanically Attached at 16 fasteners per 4’ X 8’ board.

Membrane: Any Fully Adhered TPO or PVC Roof

750lbs (340kg)


1-7

Deck: Min ½” Wood, Metal, Lightweight Concrete, or Structural Concrete. 

Cover Board:  Min ½” High Density ISO, Ribbon Adhered at 12” O.C.

Membrane: Any Fully Adhered TPO or PVC Roof

650lbs (295kg)

test7-300x197.jpg

1-8

Deck: Min ½” Wood, Metal, Lightweight Concrete, or Structural Concrete. 

Cover Board: Min ½” High Density ISO, Mechanically Attached at 16 fasteners per 4’ X 8’ board.

Membrane: Any Fully Adhered TPO or PVC Roof

1050lbs (476kg)

test-photo-5-300x250.jpg

1-9

Deck: Min ½” Wood, Metal, Lightweight Concrete, or Structural Concrete. 

Insulation Board: Any UL Classified Min 1.5” Ribbon Adhered ISO Board.

Membrane: Any Fully Adhered TPO or PVC Roof

700lbs (318kg)

test7-300x197.jpg

1-10

Deck: Min ½” Wood, Metal, Lightweight Concrete, or Structural Concrete. 

Insulation Board: Any UL Classified Min 1.5” Mechanically Attached ISO Board.

Membrane: Any Fully Adhered TPO or PVC Roof

500lbs (227kg)


1-11

Deck: Min ½” Wood, Metal, Lightweight Concrete, or Structural Concrete. 

Insulation Board:  (optional) Any UL Classified Min 1.5” Mechanically Attached or Ribbon Adhered ISO Board.

Cover Board: (optional) Min ¼” Dens-Deck Prime, Securock, Mechanically Attached Ribbon or Adhered.

Membrane: Any Fully Adhered or Mechanically Attached PO or PVC roof membrane

991lbs (450kg)

test12-300x237.jpg